ACT ACT5 PROX Manuale Utente Pagina 8

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 12
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 7
8
N/O
Comm
N/C
BATCH:
PRODUCT
SERIAL NUMBER
01XX-
ACT5prox
00XXX X
Note
:
The ACT5prox may be powered
from 12 or 24V AC or DC.
Door Release
Button
Power
Supply Unit
This illustration shows wiring
for normally de-energised
locks. If normally energised
locks are required, use the
N/C relay contacts .
Important!
Always Place Varistor
Across Lock Terminals
+12V
0V
12-24V
AC/DC
Push Button
0V
SCHRACK
12V = DC
5A/250V ~AC
LK1
Power up without link if
Programming code has been lost
ACT5prox Wiring Diagram for Door Strike Locks
Fig 1
ACT5prox Operating and Installation Instructions
Act 12pp ACT5prox:Act 20pp 1.1 English 14/11/2007 13:10 Page 8